Tfc-group Famoso 1000 (Hard Wired) Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Relais Tfc-group Famoso 1000 (Hard Wired). TFC Group Famoso 1000 (Hard Wired) User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 3
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Grässlin (UK) Ltd
Famoso 1000: Short Form Programming Guide
General description (standard hard-wired unit)
The Famoso 1000 is a battery-powered, digital timer / thermostat. This
unit can be pre-programmed to provide day-time temperature control,
and night set-back temperature control. Each day can be programmed
with the same – or different – time sequences of day time / night time
temperature periods. Once the programme is running, the unit can be
temporarily or permanently overridden to increase or decrease the
desired temperature setting. Use only good quality AA size alkaline
batteries, which should run the unit for approximately 18 months to 2
years (actual running time dependent on the way the unit is
programmed, number of switching operations etc.). When the batteries
need replacing, a low battery symbol flashes in the display.
Fitting instructions (standard hard wired unit)
Fit the removable backplate to the wall, and connect live in / live out to the two screw terminals which are accessible
under the removable cover. The order of connection does not matter as the terminals simply connect to a normally
open switch. If replacing a conventional room-thermostat, and there is a neutral wire, this should not be connected
to the Famoso 1000, but should be ‘made safe’ by taping up, or by ‘parking’ in a separate screw terminal connector.
Now clip the Famoso 1000 body to the backplate, and you are ready to set the time and the programme you
require. Famoso 1000 RF needs no wiring – see supplementary information leaflet.
Programming (standard unit and RF version)
Set the time – when the batteries are first inserted, the full display is visible for approx. 3 seconds, then the clock
symbol and hour (reading 12) flash. Press + or – button to change the hour, once this is correct, press ok. Now
press + or – to change the minute, then press ok again. Press + or – to change the weekday to the current day (1 =
Monday, 7 = Sunday), then press ok again. Press + or – to set your desired day-time temperature level, then press
ok. Press + or – to set the desired night set-back temperature, and press ok.
Set the programme – after completion of setting time, day, then day and night temperatures, you can now
programme the ‘profile’ of day and night temperatures for each 24 hour period of each day. You can choose from
four pre-set programmes – please see the table below. Press the + or – button to scroll through the options from
P1 to P4, and then press ok to select for that day. The programmes are presented automatically beginning with
Monday, and with each press of the ok button, you move to the next day of the week.
Programme Day temperature operative between: Night temperature operative between:
P1 07:00 – 23:00 23:00 – 06:59
P2 06:00 – 09:00 and 17:00 – 22:00 09:00 –16:59 and 22:00 – 05:59
P3 24 hours No night temperature period
P4 No day temperature period 24 hours
Setting your own programme
If you wish to set your own timed sequence, press + or – until you see Pd in the display. Press ok and 0:00 appears
in the display. Press the – button (which also has a moon
symbol printed next to it) repeatedly, and you are
programming in 30 minute increments – starting from midnight on the day in question – the night set-back
temperature level. Once you reach the time in the morning when you wish to have day-time temperature control,
start pressing the + button (which also has a sun
symbol printed next to it). You will now be programming the
day-time temperature level in 30 minute increments, and you will begin to see the graphic symbol at the bottom of
the display representing this sequence. If you require a return to night set-back level from mid-morning until later in
the day, again press the - /
button repeatedly, and you are programming night set-back temperature in 30
minute increments. Using the - /
and + /
buttons, complete your day-time and set-back temperature
sequence for the day, and press the ok button. The display shows the next day, and you can – once again – select
with + or – buttons, P1 to P4, as well as Pd. Pd selection will now show the sequence you programmed earlier, so
that you can simply accept a repeat of this sequence if required, or starting from 0:00 on the day in question, use
the - /
and + /
buttons if you wish to programme a different timed sequence of day-time and set-back
temperature periods.
Manual override
Once programming is complete (having finished the programme for day 7 and pressed ok), the Famoso 1000 goes
into automatic mode, and will now control according to the sequence just programmed. You can select continuous
day-time or night set-back temperature by pressing the top button on the keypad – the operating mode button.
Please see the instruction booklet supplied for a full explanation of the operating modes. Alternatively, you can
temporarily override the temperature – up or down – by pressing the + or – key. In automatic mode, this will (until
the next programmed sequence) adjust the set temperature up or down to the desired level. The hand symbol
shows in the display, indicating this setting will self-reset with the next timed function. At any time you can restore
automatic operation by pressing the ok button.
Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - Grässlin (UK) Ltd

Grässlin (UK) Ltd Famoso 1000: Short Form Programming Guide General description (standard hard-wired unit) The Famoso 1000 is a battery-powered,

Page 2

Grässlin (UK) Ltd Famoso 1000 RF: Supplementary information General description The Famoso 1000 is a battery-powered, digital timer / thermostat.

Page 3 - Famoso 1000 RF - wiring

Famoso 1000 RF - wiring Neutral Live Link wire*Switched live (output) 654321230V A link-wire should be fitted when the load requires a mains-input. S

Commentaires sur ces manuels